Fire Resistant Black Sheath 4 Core Copper Armoured Cable

Brand Name : CHINT

Model Number : YJV22

Certification : CCC/KEMA/SGS

Place of Origin : CHINA

MOQ : Negotiable

Price : Negotiable

Supply Ability : 500KM/Month

Packaging Details : wooden/iorn drum

Name : Copper Armoured Cable

Feature : Fire Resistant

Outer Sheath : PVC/MDPE

Rated Voltage : 0.6/1kV

Sheath : Black Sheath

Port : Shanghai

Contact Now

Fire Resistant Black Sheath 4 Core Copper Armoured Cable

Copper Armoured Cable Application


For laying in tunels in door,tunnel,channel and underground.Able to bear external mechanical force,but unable to bear large pulling force.


Copper Armoured Cable Description


Conductor:Class 2

Insulation:XLPE

Sheath: PVC

Cable Speciification: Fire Resistant

Marking: Embossing Or Printing


Construction


Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with IEC 60228

Insulation : 90°C cross linked XLPE insulation complying with IEC 60502-1

Interlining: PVC type ST2 to IEC 60502, black

Armouring: STA(Steel-Tape Armouring)

Sheath : PVC type ST2 to IEC 60502, black


Standards:


International: IEC 60502, IEC 60228, IEC 60332, IEC 60754

China: GB∕T 12706.1-2008, GB∕T 19666-2005

Other standards such as BS,VDE and ICEA upon request


Copper Armoured Cable Technical data


Rated voltage: 0.6/1kV

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables


Copper Armoured Cable Technical Specifications


Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulationThickness of steel tapeSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×107/1.330.70.21.811.82651.833.57794
1×167/1.670.70.21.812.83381.153.5100120
1×257/2.100.90.21.814.54580.7273.5130155
1×357/2.480.90.21.815.65710.5243.5160185
1×5010/2.561.00.21.816.87120.3873.5195220
1×7014/2.561.10.21.818.79400.2683.5245270
1×9519/2.561.10.21.820.312090.1933.5300320
1×12024/2.561.20.21.822.014650.1533.5349365
1×15030/2.561.40.21.823.817570.1243.5400410
1×18537/2.561.60.21.825.921570.09913.5465465
1×24048/2.581.70.21.828.327320.07543.5550540
1×30060/2.581.80.21.930.933440.06013.5635610
1×40060/2.932.00.2234.442600.0473.5745695
1×50060/3.332.20.52.239.656730.03663.5860780
1×63060/3.762.40.52.344.071330.02833.5990880
2×1.51/1.380.70.21.812.323012.13.52031
2×2.51/1.760.70.21.813.12667.563.52741
2×41/2.230.70.21.814.03164.613.53553
2×61/2.740.70.21.815.03783.083.54566
2×107/1.330.70.21.817.55161.833.56390
2×167/1.670.70.21.819.56721.153.584117
2×257/2.100.90.21.822.99370.7273.5113151
2×357/2.480.90.21.825.211810.5243.5139181
2×5010/2.561.00.21.821.812810.3873.5161210
2×7014/2.561.10.21.924.817340.2683.5204257
2×9519/2.561.10.2227.522780.1933.5252310
2×12024/2.561.20.52.231.330950.1533.5291351
2×15030/2.561.40.52.334.537300.1243.5333393
2×18537/2.561.60.52.538.246180.09913.5385445
2×24048/2.561.70.52.642.258320.07543.5457516
2×30060/2.561.80.52.846.371420.06013.5527583
3×1.51/1.380.70.21.812.725612.13.52031
3×2.51/1.760.70.21.813.53027.563.52741
3×41/2.230.70.21.814.63674.613.53553
3×61/2.740.70.21.815.74493.083.54566
3×107/1.330.70.21.818.46271.833.56390
3×167/1.670.70.21.820.58381.153.584117
3×257/2.100.90.21.824.211910.7273.5113151
3×357/2.480.90.21.826.615280.5243.5139181
3×5010/2.561.00.21.925.518140.3873.5161210
3×7014/2.561.10.2229.024740.2683.5204257
3×9519/2.561.10.52.133.535980.1933.5252310
3×12024/2.561.20.52.336.743860.1533.5291351
3×15030/2.561.40.52.440.753320.1243.5333393
3×18537/2.561.60.52.544.665620.09913.5385445
3×24048/2.561.70.52.850.284140.07543.5457516
3×30060/2.561.80.52.954.9103060.06013.5527583
4×1.51/1.380.70.21.813.529112.13.52031
4×2.51/1.760.70.21.814.43487.563.52741
4×41/2.230.70.21.815.54304.613.53553
4×61/2.740.70.21.816.75343.083.54566
4×107/1.330.70.21.819.87581.833.56390
4×167/1.670.70.21.822.210271.153.584117
4×257/2.100.90.21.826.314790.7273.5113151
4×357/2.480.90.21.829.119140.5243.5139181
4×5010/2.561.00.2228.423340.3873.5161210
4×7014/2.561.10.52.133.635180.2683.5204257
4×9519/2.561.10.52.337.946380.1933.5252310
4×12024/2.561.20.52.441.857010.1533.5291351
4×15030/2.561.40.52.646.069120.1243.5333393
4×18537/2.561.60.52.751.085620.09913.5385445
4×24048/2.561.70.5357.7110520.07543.5457516
4×30060/2.561.80.53.162.7134790.06013.5527583
5×1.51/1.380.70.21.814.332812.13.52031
5×2.51/1.760.70.21.815.33977.563.52741
5×41/2.230.70.21.816.64974.613.53553
5×61/2.740.70.21.818.06233.083.54566
5×107/1.330.70.21.821.48951.833.56390
5×167/1.670.70.21.824.112251.153.584117
5×257/2.100.90.21.828.717800.7273.5113151
5×357/2.480.90.21.931.923290.5243.5139181
5×5019/1.861.00.22.131.928790.3873.5161210
5×7014/2.561.10.52.237.843270.2683.5204257
5×9519/2.561.10.52.442.857400.1933.5252310
5×12024/2.561.20.52.546.870270.1533.5291351
5×15030/2.561.40.52.752.185910.1243.5333393
5×18537/2.561.60.52.957.5106360.09913.5385445
5×24048/2.561.70.53.264.5136510.07543.5457516
5×30060/2.561.80.53.471.0167640.06013.5527583
3×2.5+1×1.51/1.760.70.21.814.13347.563.52741
3×4+1×2.51/2.230.70.21.815.24104.613.53553
3×6+1×41/2.740.70.21.816.45083.083.54566
3×10+1×67/1.330.70.21.819.07011.833.56390
3×16+1×107/1.670.70.21.821.69591.153.584117
3×25+1×167/2.100.90.21.825.313650.7273.5113151
3×35+1×167/2.480.90.21.827.416890.5243.5139181
3×50+1×2510/2.561.00.21.927.921150.3873.5161210
3×70+1×3514/2.561.10.2232.128960.2683.5204257
3×95+1×5019/2.561.10.52.237.442130.1933.5252310
3×120+1×7024/2.561.20.52.341.452510.1533.5291351
3×150+1×7030/2.561.40.52.445.061750.1243.5333393
3×185+1×9537/2.561.60.52.650.077310.09913.5385445
3×240+1×12048/2.561.70.52.856.098570.07543.5457516
3×300+1×15060/2.561.80.5361.3120420.06013.5527583
3×2.5+2×1.51/1.760.70.21.814.93697.563.52741
3×4+2×2.51/2.230.70.21.816.14574.613.53553
3×6+2×41/2.740.70.21.817.45733.083.54566
3×10+2×67/1.330.70.21.820.07851.833.56390
3×16+2×107/1.670.70.21.823.010921.153.584117
3×25+2×167/2.100.90.21.826.815560.7273.5113151
3×35+2×167/2.480.90.21.828.718740.5243.5139181
3×50+2×2510/2.561.00.2229.123840.3873.5161210
3×70+2×3514/2.561.10.52.134.435830.2683.5204257
3×95+2×5019/2.561.10.52.338.546920.1933.5252310
3×120+2×7024/2.561.20.52.442.559090.1533.5291351
3×150+2×7030/2.561.40.52.546.868890.1243.5333393
3×185+2×9537/2.561.60.52.752.587440.09913.5385445
3×240+2×12048/2.561.70.52.958.5110680.07543.5457516
3×300+2×15060/2.561.80.53.164.5135510.06013.5527583
4×2.5+1×1.51/1.760.70.21.815.13837.563.52741
4×4+1×2.51/2.230.70.21.816.44774.613.53553
4×6+1×41/2.740.70.21.817.75983.083.54566
4×10+1×67/1.330.70.21.820.78391.833.56390
4×16+1×107/1.670.70.21.823.511591.153.584117
4×25+1×167/2.100.90.21.827.716670.7273.5113151
4×35+1×167/2.480.90.21.930.421070.5243.5139181
4×50+1×2510/2.561.00.2229.525900.3873.5161210
4×70+1×3514/2.561.10.52.235.039000.2683.5204257
4×95+1×5019/2.561.10.52.339.351440.1933.5252310
4×120+1×7024/2.561.20.52.543.263860.1533.5291351
4×150+1×7030/2.561.40.52.648.376830.1243.5333393
4×185+1×9537/2.561.60.52.853.295660.09913.5385445
4×240+1×12048/2.561.70.5359.7122190.07543.5457516
4×300+1×15060/2.561.80.53.365.6149850.06013.5527583

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

Armored or unarmored. If armor, the armor type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement


PACKING AND SHIPPING

All cable for exporting are well packed and protected by wooden drum or Wood and Steel Drum.

The packing material is depended on the weight and size of cable.

The good information, manufacture information, and the client's information is firmly printed on each size of drum.


After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.

The size of the container is chosen according to weight of total loaded goods or as per the client's requirement.



Product Tags:

Fire Resistant pvc armoured cable

      

4 Core armored power cable

      
Cheap Fire Resistant Black Sheath 4 Core Copper Armoured Cable wholesale

Fire Resistant Black Sheath 4 Core Copper Armoured Cable Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhejiang CHINT Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)